# Steel Checks to AISC LRFD
The steel design check supports the AISC LRFD 3rd edition. See Steel Checks to AISC 360 for later versions.
The input data requirements are the same as for BS5950-1:2000.
The effect sway of frame on the effective length of members has not been considered in member buckling check.