Skip to main content

Edit Buckling Factors

Icon
Edit Buckling Factors

Description

Modify GSA Equivalent uniform moment factor for LTB for 1D Member

Input parameters

Icon Type Name Description
BucklingFactorsParamBuckling FactorsBuckling FactorsEquivalent uniform moment factor for LTB for 1D Member parameter
NumberParamNumberFactor LsyMoment Amplification Factor, Strong Axis
NumberParamNumberFactor LszMoment Amplification Factor, Weak Axis
NumberParamNumberEquivalent uniform moment factor for LTBOverride the automatically calculated factor to account for the shape of the moment diagram in lateral torsional buckling design equations. This override is applied for all bending segments in the member. This override is applied to the following variable for each design code:
AISC 360: C_b
AS 4100: alpha_m
BS 5950: m_LT
CSA S16: omega_2
EN 1993-1-1 and EN 1993-1-2: C_1
Hong Kong Code of Practice: m_LT
IS 800: C_mLT
SANS 10162-1: omega_2

Output parameters

Icon Type Name Description
BucklingFactorsParamBuckling FactorsBuckling FactorsGSA Equivalent uniform moment factor for LTB for 1D Member parameter
NumberParamNumberFactor LsyMoment Amplification Factor, Strong Axis
NumberParamNumberFactor LszMoment Amplification Factor, Weak Axis
NumberParamNumberEquivalent uniform moment factor for LTBOverride the automatically calculated factor to account for the shape of the moment diagram in lateral torsional buckling design equations. This override is applied for all bending segments in the member. This override is applied to the following variable for each design code:
AISC 360: C_b
AS 4100: alpha_m
BS 5950: m_LT
CSA S16: omega_2
EN 1993-1-1 and EN 1993-1-2: C_1
Hong Kong Code of Practice: m_LT
IS 800: C_mLT
SANS 10162-1: omega_2