EN 1993 National Annexes
The following nationally defined parameters are used.
EN 1993-1-1:2005 Eurocode 3 (generic):
The following parameters are used for design checks to EN 1993-1-1:2005 Eurocode 3.
Clause 6.1 (1)
, and
Clause 6.3.2.2.
Table 6.3 is used for imperfection factors.
Clause 6.3.2.3 (1)
, and table 6.5 of EN 1993-1-1:2005 are used for the lateral torsional buckling curve. For the sections not available in the table, buckling curve d is used.
Clause 6.3.2.3 (2)
and ; Table 6.6 are used for the correction factor .
Interaction factors:
Annex B is used for interaction factors. For other than doubly symmetric sections, the value used for calculating interaction factors in any direction (say or ) is the largest value of the following three
- or depending on the direction.
- for torsion.
- for flexural torsion.
Table B.3 is used for equivalent uniform moment factors; steel checker assumes that the spans are loaded with uniform loading.
Effective Length:
Effective buckling lengths for flexural buckling are calculated in accordance with Table 22 of BS5950-1:2000.
BS EN 1993-1-1:2005 Eurocode 3 (GB):
The following parameters are used for design checks to the UK National Annex to EN 1993-1-1:2005 Eurocode 3.
Clause 6.1 (1)
, and
Clause 6.3.2.2.
Table 6.3 is used for imperfection factors.
Clause 6.3.2.3 (1)
For rolled sections and hot-finished and cold-formed hollow sections:
,
Welded sections:
,
Table in clause 2.17 of UK NA to EN 1993-1-1:2005 is used for the lateral torsional buckling curve. For the sections not available in the table, buckling curve d is used.
Clause 6.3.2.3 (2)
Clause NA 2.18 is used to calculation modification factor, .
Interaction factors:
As for Eurocode 3 (generic).
Effective Length:
Effective buckling lengths for flexural buckling are calculated in accordance with Table 22 of BS5950-1:2000.
BS EN 1993-1-2:2005 (fire) Eurocode 3 (GB):
The following parameters are used for design checks to the UK National Annex to EN 1993-1-1:2005 Eurocode 3.
...
DIN EN 1993-1-1:2005 Eurocode 3 (DE):
The following parameters are used for design checks to the German National Annex to EN 1993-1-1:2005 Eurocode 3.
Clause 6.1 (1)
, and
Clause 6.3.2.3 (2)
The coefficient is calculated as for Eurocode 3 (generic).
I.S. EN 1993-1-1:2005 Eurocode 3 (IE)
The following parameters are used for design checks to the UK National Annex to EN 1993-1-1:2005 Eurocode 3.
...
NEN-EN 1993-1-1:2005 Eurocode 3 (NL):
The following parameters are used for design checks to the Netherlands National Annex to EN 1993-1-1:2005 Eurocode 3.
Clause 6.1 (1)
, and
Clause 6.3.2.2.
Table 6.3 is used for imperfection factors.
Clause 6.3.2.3 (1)
, and table 6.5 of EN 1993-1-1:2005 are used for the lateral torsional buckling curve. For the sections not available in the table, buckling curve d is used.
Clause 6.3.2.3 (2)