Footfall Analysis
Footfall analysis (or in full, footfall induced vibration analysis) is used to calculate the elastic vertical nodal responses (acceleration, velocity, response factor etc.) of structures to human footfall loads (excitations). The human footfall loads are taken as periodic loads. Using to Fourier Series, the period footfall loads can be expressed as:
where is the body weight of the individual, and are the Fourier coefficients (or dynamic load factor), the actual values of dynamic load factors can be found from reference 37 (A Design Guide for Footfall Induced Vibration of Structures) in the bibliography, is the period of the footfall (inverse of walking frequency) and the number of Fourier (harmonic) terms to be considered, 4 is used for walking on floor using CCIP-016 method, 3 is used for walking on floor using SCI method and 2 is used for walking on stairs.
After subtracting the static weight of the individual (since it does not vary with time and does not induce any dynamic response), the dynamic part of the footfall loads are the sum of a number of harmonic loads
There are two distinctive responses from the footfall excitation, the resonant (steady state) and transient. If the minimum natural frequency of a structure is higher than 4 times the highest walking frequency (see reference 37), the resonant response is normally not excited since the natural frequencies of the structure are so far from the walking (excitation) frequency, therefore the transient response is normally in control, otherwise, the resonant response is probably in control. Both resonant (steady state) and transient analyses are considered in GSA footfall analysis, so the maximum responses will always be captured.
Resonant response analysis
As footfall loads are composed of a number of harmonic loads (components), harmonic analysis is used to get the responses for each of the harmonic components of footfall loads and then to combined them to get the total responses. From one of the harmonic components of the footfall loads in equation above and the given walking frequency , the following dynamic equation of motion can be obtained
where is a unit vector used to define the location of the harmonic load. All the components in this vector are zero except the term that corresponds to the vertical direction of the node subjected footfall load.
Since the number of footfalls is limited and the full resonant response from the equation above may not always be achieved, a reduction factor for the dynamic magnification factors is needed to account for this non-full resonant response. The reduction factor can be calculated from
Where is damping ratio of mode m and with the harmonic load number and the number of footfalls.
Applying this reduction factor to the dynamic magnification factors in Harmonic Analysis, this equation can be solved using the method described in Harmonic Analysis Theory section. Repeating this analysis, the responses from the other harmonic loads of the footfall can also be obtained.
For each harmonic, the approach from reference 37 is to find the maximum acceleration and velocity. The method gives us two values, , the peak acceleration for that harmonic, and , the peak velocity for that harmonic, with .
From this, we can compute the RMS values, which will be and . These peak and RMS values are then combined across all harmonics using square-root-sum-of-squares, so: