# Seismic Analysis: Equivalent Static Procedures
In many cases simplified analysis methods using equivalent static loading are used in seismic analysis. The static loading to be considered will normally be defined with reference to a design code.
# Equivalent Static
The equivalent static load is based on the base shear, which in turn depends on the period of the building. This can either be specified directly or based on the code approximation. The code period is usually defined as a function of the height of the building
The coefficients
GSA uses the details defined for the response spectrum along with the weight of the building and the period to calculate the base shear,
where
# Accidental Torsion
The equivalent static load procedures require accidental torsion loads to be considered. These are to represent the effect of a displacement of the centre of mass of the storeys. In GSA the accidental torsion loads are calculated so that the moment applied to the storey is proportional to the equivalent static storey forces
This depends on the building dimension d at the storey level which is determined by GSA. The factor
GSA generates a set of nodal forces that create a moment for the storey that satisfies the equation above without generating any lateral force, so that this can be used n conjunction with the equivalent static load.