# Response Spectrum Wizard : UBC (1997)
The UBC 1997 spectrum is defined by a set of parameters defined in the code.
Zone Number
This is the Zone in which the structure is to be located and is one of 1, 2A, 2B, 3, 4 as defined in Table 23-I).
Seismic Source Type
For Zone 4 the seismic source type is categorised by types A, B or C determined form Table 16-U.
Closest Distance to Known Seismic Source
For Zone 4 the spectrum will depend on the distance to a known seismic source in the range 2km to 15km. See Table 16.
Soil Type
Enter SA, SB, SC, SD or SE for the soil type as described in Section 1636. Type SF soil requires specialist geotechnical advice.
Importance Factor
Determine the importance factor (
Structural System Factor
The structural system factor (
Empirical Building Period
Enter the value of the empirical building period derived from the code (Section 1630.2.2) or set to zero for automatic calculation based on frame type.
Frame Type and Building Period Coefficient
The empirical period of the building (Section 1630.2.2 – Method A) is calculated from equation (30-8)
The building period coefficient,
- Steel moment-resisting
- Reinforced concrete moment-resisting
- Eccentrically braced
- Other
And
This is ignored if the building period is specified directly.
Target Base Shear
Select from 90% or 100% as determined from Section 1631.5.4.
Factor for Vertical Excitation
It is common to reduce the spectral values for vertical excitation to ⅔ of that used for horizontal excitation.
Ignore Short Period Force Reduction
It may be unconservative to reduce spectral values for low periods. This option ignores the reduction and extends the plateau to cover the low periods.